MESSKO MTRAB Breather

Maintenance-free dehydrating breathers

 

The MTRAB® 2.5 DB100 with alpha-control is a condition-controlled system, recommended for use on tap changers, arc suppression coils, air-filled cable terminal boxes and traction transformers. The desiccant is regenerated depending on the condition. Silica gel fill level: 1,1 kg with α-control.

Good to know: The main function of dehydrating breathers is to dehumidify the ambient air. As a result of the thermal compression of the insulation medium, the ambient air flows from the environment to the expansion tank of the transformer and tap changer (referred to as inhalation). During inhalation, moisture must be prevented from penetrating into the equipment with the air flow, as this reduces the insulating effect due to the contamination of the insulating medium.

 

The MTRAB® 2.5 DB200D with beta-control is a self-learning system, recommended for use on transformers with cyclic loads (generator transformers, network coupling transformers, phase shifters, reactors, HVDC transformers). In addition to monitoring the humidity, the device determines a time window in which the oil conservator exhales and the desiccant is regenerated. Silica gel fill level: 2 x 2,2 kg with β-control.

Good to know: The main function of dehydrating breathers is to dehumidify the ambient air. As a result of the thermal compression of the insulation medium, the ambient air flows from the environment to the expansion tank of the transformer and tap changer (referred to as inhalation). During inhalation, moisture must be prevented from penetrating into the equipment with the air flow, as this reduces the insulating effect due to the contamination of the insulating medium.

 

The MTRAB® 2.5 DB200T with beta-control is a self-learning system, recommended for use on transformers with cyclic loads (network transformers, step-up transformers, phase shifters, reactors). In addition to monitoring the humidity, the device determines a time window in which the oil conservator exhales and the desiccant is regenerated. Silica gel fill level: 2,2 kg with β-control.

Good to know: The main function of dehydrating breathers is to dehumidify the ambient air. As a result of the thermal compression of the insulation medium, the ambient air flows from the environment to the expansion tank of the transformer and tap changer (referred to as inhalation). During inhalation, moisture must be prevented from penetrating into the equipment with the air flow, as this reduces the insulating effect due to the contamination of the insulating medium.

MESSKO MTRAB Breather

$4,452.14Price
Quantity
  • MESSKO

Don't see the SKU you need?

Request the right model number below.

Version
Type
Sensor Type
Thread Joint
Measuring Range
Capillary Tube Length
Number of Switches
Electrical Connection
Housing
635-305265
Universal Retrofit Temperature Gauge Analog Output
Retrofit-Sensor
7/8"-14UNF
0°C ... +160°C
6m
4
4x 3/4"-14 NPT female thread
RAL 7038, retrofit
635-305264
Universal Retrofit Temperature Gauge
Retrofit-Sensor
7/8"-14UNF
0°C ... +160°C
6m
4
4x 3/4"-14 NPT female thread
RAL 7038, retrofit
635-305260
Universal Retrofit Temperature Gauge
Retrofit-Sensor
7/8"-14UNF
0°C ... +160°C
6m
3
ANSI
RAL 7038, retrofit
635-305800
Universal Retrofit Temperature Gauge
Retrofit-Sensor
7/8"-14UNF
0°C ... +160°C
6m
4
ANSI
RAL 7038, retrofit
635-306684
Compact Winding Analog Output
US-Sensor No 7RM
7/8"-14UNF
0°C ... +180°C
4m
4
4x 3/4"-14 NPT female thread
RAL 7038, bracket
635-306683
Compact Winding Analog Output
US-Sensor No 7RM
7/8"-14UNF
0°C ... +180°C
4m
4
4x 3/4"-14 NPT female thread
RAL 7038, bracket
635-306664
Compact Oil Analog Output
US-Sensor No 7RM
7/8"-14UNF
0°C ... +160°C
4m
4
4x 3/4"-14 NPT female thread
RAL 7038, bracket
635-306663
Compact Oil Temperature Gauge
US-Sensor No 7RM
7/8"-14UNF
0°C ... +160°C
4m
4
4x 3/4"-14 NPT female thread
RAL 7038, bracket